DQC Safety Light Curtain (ESPE)

A safety light curtain for industrial automation. Square 30×30 mm profile with resolutions 10/14/20/25/30/40/80/200 mm; standard sensing range 0.3–3 m (optional 0.3–6 m); strong light immunity ≥10,000 Lux (incidence ≥ 5°); response time ≤ 15 ms; enclosure rating IP65. Dual-channel NPN/PNP safety outputs (NO/NC), with OSSD, EDM, and optical synchronization.

DQC Safety Light Curtain main image
Product Highlights
  • High resolution: Minimum beam spacing of 10mm, supporting fine detection (Resolution), suitable for finger protection (Finger Protection).
  • High protection rating: IP65, dustproof and waterproof (Dustproof and Waterproof), suitable for harsh industrial environments.
  • Self-test function: Built-in self-diagnostic system (Self-Monitoring), real-time monitoring of beam status to ensure system reliability; supports external device monitoring (External Device Monitoring, EDM).
  • Strong anti-interference capability: Effectively resists electromagnetic interference (EMI), light interference (Ambient Light Immunity >10000 Lux), and vibration, with anti-interference signal up to 9%; response time (Response Time) less than 15ms.
  • Solid-state output: Uses output signal switching device (Output Signal Switching Device, OSSD), dual-channel output (Dual Channel), PNP/NPN optional, no mechanical wear, long lifespan.
  • Easy installation: Aluminum alloy housing (Aluminum Alloy Housing), lightweight and durable, supports various installation methods; equipped with status indicators (Status Indicators) to display operating status.
  • Multi-beam configuration: Number of beams optional 4-32, supports blanking function (Blanking) to ignore fixed objects, muting function (Muting) to allow material passage.
  • Safety output: Supports restart interlock (Restart Interlock) to ensure safe recovery.

Data normalized from the provided manual pages; if differences exist, the official datasheet/warranty documents prevail.

Resolution & Application Guide
Resolution (K)Typical Application
10 mm / 14 mmFinger protection (assembly, fixtures, close-to-hazard stations)
20 mm / 25 mm / 30 mmPalm protection (packaging, access openings)
40 mm / 80 mm / 200 mmHand/arm or body presence (aisles, zone guarding)

Protective height H = (n − 1) × K. Overall length L = H + addon (varies by K; see spec tables below).

Technical Parameters (DQC Series)

CategoryItemTypical Value / OptionNotes
OpticalOperating principleThrough-beam infrared LED, modulatedEmitter/receiver pair; filtering and anti-interference design
Resolution (K)10 / 14 / 20 / 25 / 30 / 40 / 80 / 200 mmFinger / Palm / Hand-arm or Body
Protective height (H)H = (n−1) × Kn = number of beams
Response time≤ 15 msVaries with beam count
Ambient light immunity≥ 10,000 LuxIncidence ≥ 5°
Sensing range0.3–3 m (standard); 0.3–6 m (optional)Specify on order
Electrical / I/OSupplyDC 12/24 V; AC 110–220 V (with controller)Reverse/over-voltage protection
Safety outputsDual-channel NPN / PNP, NO/NC selectable (OSSD)Sink current 500 mA; short-circuit protection
Channel capability≤ 200 mA (typ.)Transistor output
ProtectionShort / Over-current / Over-load / Reverse polarityAuto recovery
IndicatorsPower / Run / BlockedClear indication
ConnectorCircular aviation connectorWaterproof, optional lengths
SynchronizationOpticalFewer cables, stronger immunity
Mechanical / EnvironmentBody section30 × 30 mm (square)ABS plastic nylon
Overall lengthL = H + addon (varies by K)Approx. values; see tables
Ingress protectionIP65Dust-tight, water-jet resistant
Operating temp.−10 ~ +40 °CStorage −25 ~ +55 °C
HumidityOperating 35–85 %RHStorage 35–95 %RH
ComplianceStandardsIEC 61496-1/-2 (Type 4), EN ISO 13849-1 (PL e)Safety distance per ISO 13855
CertificationsCE, UL, TÜVRefer to delivered certificates
System integrationSafety relay / Safety PLCIndependent dual inputs; EDM support

DQC Series Detailed Specifications

Tables list typical beam counts (n) for each resolution (K) with protective height H and overall length L. Model format: DQCnn/K-H. Example: DQC06/10-50 (K=10, n=6, H=50). Output: Add A/B/C/D (PNP NO / PNP NC / NPN NO / NPN NC).

K (mm)Beams nProtective Height H (mm)Overall Length L (mm)Model ExampleRange
10650111DQC06/10-500.3–3 m
10870131DQC08/10-700.3–3 m
101090151DQC10/10-900.3–3 m
1012110171DQC12/10-1100.3–3 m
1014130191DQC14/10-1300.3–3 m
1016150211DQC16/10-1500.3–3 m
1018170231DQC18/10-1700.3–3 m
1020190251DQC20/10-1900.3–3 m
1022210271DQC22/10-2100.3–3 m
1024230291DQC24/10-2300.3–3 m
1026250311DQC26/10-2500.3–3 m
1028270331DQC28/10-2700.3–3 m
1030290351DQC30/10-2900.3–3 m
1032310371DQC32/10-3100.3–3 m

For 0.3–6 m builds, specify on order. Keep the model format DQCnn/K-H. Add A/B/C/D for output type (PNP NO / PNP NC / NPN NO / NPN NC).

Typical Applications

  • Presses / shears / press brakes: 10–30 mm resolutions suit hand protection; fast response enables shorter safety distance.
  • Assembly fixtures & robot periphery: finger/palm detection with interlocked safety loop; easy maintenance.
  • Packaging / logistics: 40–200 mm for aisle and presence detection.
  • General machinery: integrate with a safety relay/PLC for stop, interlock and EDM monitoring.

Safety distance reference (ISO 13855): S = K × T + C, where T is machine stopping time.

Installation Method

Determine the installation method: Side installation method (This item is sent by default), Two-end installation method, Tubular installation method.

Finger protection Spacing 10mm, Palm protection Spacing 20mm, Arm or body protection Spacing 40mm.

The DQC series safety light curtains can be used in conjunction with the following optional accessories.

Mutual shooting distance: It is suggested that you inform us of the actual range to achieve a better detection effect.

Protection height: The distance between the highest light spot and the lowest light spot is the range of the area that can be sensed on the grating.

Working Principle

The working principle of the DQC series safety light curtain is based on through-beam photoelectric sensing technology, using infrared beams to create a virtual protective barrier. The specific process is as follows:

  1. Beam Emission and Reception: The emitter emits modulated infrared beams, and the receiver detects light intensity.
  2. Synchronization Mechanism: Optical synchronization to ensure alignment.
  3. Detection of Interruption: Object interrupts beam, triggering alarm.
  4. Signal Processing: MCU processes, OSSD outputs OFF to stop machine.
  5. Recovery: Restart interlock for recovery.
  6. Anti-Interference: Filters to filter interference.
inXfrWA✉︎PTG